BTS-4

Q-125 TUBING

TECHNICAL DATA

              MAKE-UP TORQUE TENSILE INTERNAL COLLAPSE STRING CONN. SPEC. MAKE
  SIZE   WT/FT PIPE WALL DRIFT CONN. CONN. (FT/LBS) YIELD PRESSURE
YIELD
PRESSURE
YIELD
LENGTH TENSILE CLEAR. UP
    O.D.     O.D. I.D. MIN. OPT. MAX. (LBS) (PSI) (PSI) (S.F.=1.6) EFF. O.D. LOSS
4 1/2" 21.60 4.500 .500 3.375 5.500 3.420 13250 14906 16563 785,000 24,300 24,690 22,714 105% --- 4.76
4 1/2" 24.00 4.500 .560 3.255 5.563 3.300 14500 16313 18125 866,000 27,220 27,240 22,552 104% --- 4.76
4 1/2" 26.50 4.500 .630 3.115 5.688 3.160 16000 18000 20000 957,000 30,620 30,100 22,570 104% --- 4.76


This technical data is for general information only.   Although every effort has been made to ensure accuracy, Benoit makes no warranty for any loss or damages due to its use.